Sensor Network
Description
MONILOG® Data Link Sensor – Radio base station with GPS receiver and GSM/UMTS transmission unit
Specification
Memory type/size: 512 MB
Application
GPS receiver and GSM/UMTS transmission unit
parameters
Data transmission unit
Feature
Network
- Description
- Type parameter
-
- Commodity name: Sensor Network
- Commodity ID: 1105555672343924736
- 规格1: Memory type/size: 512 MB
- 应用: GPS receiver and GSM/UMTS transmission unit
- 类型: Data transmission unit
- 特征: Network
MONILOG® Data Link Sensor – Radio base station with GPS receiver and GSM/UMTS transmission unit
Radio sensor network compromising up to 8 autonomous sensor modules
For the long-term monitoring of oversizing systems and machines
Continuously records shock, slope, temperature, humidity, pressure and incidence of light
Provide real-time monitoring of sensitive transports for optimum conditions in transport,
packaging and storage
Automatic transmission of GPS geo-position, data measurements, alarm and status signals by e-mail
Centralized GSM/UMTS transmission unit with integrated GPS receiver for exact position determination
Variable configurations for customized applications
Individually-adjustable registration and alarm thresholds, scalable number of measuring points
Ultra-long operating time and high reliability even under extreme environmental conditions
Incorporates powerful, license-free PC software, password-protected and secured against malevolent attacks
Cloud-based web portal for convenient on-line administration and tracking of transportation route
-
Up to 8 autonomous sensor modules
GPS:
Channels: 22
Antenna: SMA socket for the connection of an external active antenna 50 Ω
(3 – 30 mA/3 V/rod or cable antenna)
Mobile communications:
Frequency ranges:
Quad Band EGSM/GPRS (850/900/1800/1900 MHz)
Triple Band UMTS/HSPA (850/1900/2100 MHz)
SIM card:
Receptacle for 1,8 or 3 V SIM card
Standard SIM, micro SIM (on request)
Acceleration / Shock
(Shock-sensor modules only):
Measuring range: ±16 g (3-axes)
Tolerance: ±0,32 g
Data records: 256 curves
In case of exceeding a registration threshold of 0,3 g, a shock curve is recorded (2 kHz, 1 s)
The 256 highest shock curves are stored, optionally 3 g - 100 g (1 kHz, tolerance: ±2 g)